When switchable film (PDLC) is divided into independently driven zones, what should the order require? A page you can hand to a film processor as the requirement specification, as it stands.
We were asked what conditions to put in an order when having switchable film (PDLC) divided into independently driven zones. Rather than answer privately, we have written the answer up so that anyone in the same position can use it. The aim is a page you can hand to a film processor as the requirement specification, as it stands.
The quality of a segmentation job is nearly invisible. Incomplete cuts and scratches on the common side are hard to find even in transmitted light, and the defects surface later, in service, as heating or interference between zones. So the ordering stage is where you fix how things are measured and what numbers count as a pass.
The requirements come in two tiers. The minimum is what the buyer checks for themselves at incoming inspection — if these fail, the sheet cannot be used. The ideal is what the processor's inspection report vouches for. The meaning of each item, the pass/fail numbers and how to measure them are explained in order below.
The minimum — six checks at incoming inspection
| What to check | How |
|---|---|
| Common side intact (no partial scratches or incomplete cuts) | Visual (transmitted light) and continuity |
| Boundary separation: R_lat at or above the requirement (25 MΩ for 60 V drive) | Three resistance measurements, then the calculation (procedure below) |
| Common side fed at multiple points, all feed points shorted together | Continuity between feed points (0 Ω) |
| Zone numbers and origin marked | Visual |
| Cleanliness (no incomplete cuts, residue, debris, bubbles or foreign matter) | Transmitted light plus magnification |
| Boundary positions per drawing (±1.0 mm) | Dimensional measurement |
The ideal — vouched for by the processor's inspection report (per sheet)
| Item | Content |
|---|---|
| R_lat | Every boundary, with the raw R_adj, R_A and R_B alongside |
| Leakage to common side | R_A per zone (segment to common) |
| Thermal images | The T1 and T2 images |
| Capacitance | Per zone, with the test frequency |
| Appearance | Transmitted-light photograph |
| Scribe lines | Measured line width |
| Measurement conditions | Instrument model, test voltage, reading time, polarity, room temperature, humidity |
Every term used on this page is defined here.
| Term | Definition | Unit |
|---|---|---|
| Zone | One independently drivable region after segmentation. Numbered 1 to N; N is set in the order (our standard is 6) | — |
| Segment side | The ITO face that is divided per zone. Carries one terminal per zone | — |
| Common side | The ITO face that is not divided. Acts as the electrode shared by all zones | — |
| Scribe line | The line of removed ITO that divides the segment side into zones | — |
| V_clear | The applied voltage (RMS) at which a zone is at its clearest — where transmittance saturates on the film's V-T curve. Our controller drives up to this value and no further. Set in the order | Vrms |
| Maximum differential | The largest potential difference that can arise between two adjacent zones: one at V_clear, the other at 0 V — equal to V_clear | Vrms |
| R_adj | Resistance measured between the segment terminals of two adjacent zones (the raw reading) | Ω |
| R_A, R_B | Resistance from each of the two adjacent zones' segment terminals to the common-side terminal (= leakage to the common side) | Ω |
| R_lat (boundary resistance) | The true resistance across the boundary itself, after subtracting the return path through the common side from R_adj. The pass/fail figure | Ω |
| Panel mean temperature | Mean temperature over the whole thermal image. Hot spots are judged as a difference (+K) from this value | ℃ |
| ΔT | Temperature at any point in the thermal image minus the panel mean temperature | K |
| Feed point | A spot where an electrode (silver paste plus copper foil) contacts the film's ITO | — |
| Lead wire | The wire from a feed point to the drive board | — |
All electrical measurements follow these conditions.
| Item | Specification |
|---|---|
| Instrument | Insulation tester or digital multimeter (record model and test voltage in the inspection report) |
| Test voltage | At or below V_clear recommended (higher voltages can damage the film) |
| Reading time | The value 10 seconds after application (PDLC is ionic, so readings drift with time; if the processor has its own standard, the basis for that standard must be clearly stated) |
| Polarity | The same polarity for every measurement |
| Environment | Room temperature 23±5℃; record relative humidity |
| Drive waveform | Thermal tests are driven with AC (never DC), 50–60 Hz, at V_clear (RMS) |
| # | Area | Item | Requirement | Verified by |
|---|---|---|---|---|
| 1 | Structure | Segmentation scheme | A (standard) single-side: only the segment-side ITO is divided; the common side stays continuous and unscratched. B full both-side: both faces divided per zone, with a return wire brought out per zone | Visual, continuity |
| 2 | Structure | No half measures | Partial scratches, incomplete cuts or part-way scribe lines on the common side are not acceptable. Cut completely, or leave untouched | Visual, continuity |
| 3 | Electrical | R_lat | R_lat at or above the table below (25 MΩ or more at V_clear = 60 Vrms) | Formula below |
| 4 | Electrical | Leakage to common side | Report R_A and R_B for every zone (not used for pass/fail; characterises the film) | Measured values on record |
| 5 | Thermal | T1, full panel | Drive all zones at V_clear AC for 60 s → ΔT ≦ +3 K, no local hot spot | Thermal camera |
| 6 | Thermal | T2, boundary | Apply the maximum differential to two adjacent zones (one at V_clear, one at 0 V) for 60 s → no point on the scribe line with ΔT > +3 K | Thermal camera |
| 7 | Electrodes | Common-side feed points | Never a single point. Place them evenly, matched to the zones, at least as many as there are zones. A continuous busbar along the long edge is also acceptable | Visual, location drawing |
| 8 | Electrodes | Common-side shorting | Short all feed points together on the film so they are equipotential, then bring 1–2 wires out to the board | Continuity (0 Ω between all feed points) |
| 9 | Electrodes | If not shorted | The delivery note must state: all taps are at the same potential and must all be shorted together in use | Paperwork |
| 10 | Electrodes | Segment side | An independent terminal per zone. Mark the zone numbers and the origin (which end is zone 1) permanently on the film, and label the lead wires | Visual |
| 11 | Electrodes | Scribe-line routing | Scribe lines must not cross electrodes or busbars | Visual |
| 12 | Electrodes | Construction | Silver paste, copper foil, soldering etc. to the processor's standard. Declare the construction and electrode width | Paperwork |
| 13 | Dimensions | Boundary position tolerance | ±1.0 mm against the order drawing (negotiable by application) | Dimensional measurement |
| 14 | Dimensions | Scribe-line width | Declare, then agree a tolerance. Electrically there is ample margin (V_clear 60 V over a 0.1 mm line is 0.6 kV/mm — far from breakdown), so what matters is zero residue. Width can be set by how visible the line may be | Magnified inspection |
| 15 | Appearance | Cleanliness | No incomplete cuts, residue, debris, bubbles or foreign matter | Transmitted light plus magnification |
| 16 | Capacitance | Zone matching | Each zone's capacitance consistent with its area ratio (±10%) | LCR meter (record test frequency) |
| 17 | Reliability | Ageing | After 2 hours continuous drive at V_clear AC, re-measure #3, #5 and #6: no drop in R_lat and no new hot spots | Before/after comparison |
| 18 | Paperwork | Inspection report | As per the table under "The conclusion" above | — |
| 19 | Packing | Stress | No creases or stress on the scribe lines. State storage conditions (temperature, humidity) and shelf life | — |
There is one pass/fail axis: the resistance across the boundary between adjacent zones (R_lat) must be high enough for the drive voltage. The required value is calculated from V_clear. The basis: even if all the leakage concentrated at a single worst-case point, the heat there, P = V_clear² ÷ R_lat, stays under 0.15 mW — a local temperature rise below 5 K.
| V_clear | Required R_lat |
|---|---|
| 35 Vrms | ≧ 10 MΩ |
| 48 Vrms | ≧ 16 MΩ |
| 60 Vrms | ≧ 25 MΩ |
The table rounds the calculated floor (24 MΩ at 60 Vrms) up to round figures. Our standard is 60 Vrms (R_lat ≧ 25 MΩ).
The raw reading between adjacent terminals (R_adj) has a return path through the common-side ITO sitting in parallel with it. The return path is R_A and R_B in series (R_A + R_B), so the measured value relates to the one you want like this:
1/R_adj = 1/R_lat + 1/(R_A + R_B)
Note that this is a parallel relation — reciprocals add — not a plain subtraction. The return path has nothing to do with separation quality, so solve the relation for R_lat to remove it; that gives the formula in step 3. Without this, even a perfectly separated film reads low.
| Step | What to do |
|---|---|
| 1 | Measure between the segment terminals of two adjacent zones → R_adj |
| 2 | Measure each zone's segment terminal to the common-side terminal → R_A, R_B |
| 3 (calculate) | R_lat = 1 ÷ ( 1/R_adj − 1/(R_A + R_B) ) |
There is also a quick check. With complete separation, R_adj ≒ R_A + R_B (roughly twice the leakage to the common side). If R_adj is clearly less than that, separation is incomplete. In our own measurements, R_A and R_B were 0.7–0.8 MΩ against R_adj of 1.7 MΩ — exactly double, fully explained by the return path, so the separation was good.
Note: if the measured R_adj is equal to or larger than (R_A + R_B), the formula gives a negative or infinite value. This is not an error — it means the leakage across the boundary is below the resolution of the measurement, i.e. the separation is as good as the instrument can tell. Record it as "pass (R_lat > measurement limit)" and note the raw values.
| Feed points (contact with the film) | Lead wires (to the board) | |
|---|---|---|
| Right | Even and multiple, matched to the zones (at least as many as there are zones), or a continuous busbar along the long edge | All feed points shorted together, brought out as 1–2 wires |
| Wrong | A single point, or clustered at one end → the common-side ITO's sheet resistance drops the potential at distant zones | Kept separate per zone and wired to separate board terminals → equalising current flows through the film between zones and heats it locally |
Both are needed. The heating we once saw on our own equipment came from exactly this: six feed points, but the leads were not shorted and went to separate outputs on the board. The moment the feed points were shorted together, the heating stopped.